VC / NCT16

← Ct ScannerIn catalogue
CT Scan 16 Slices
Lower kV CT Angiography Lower kV presents a diagnostic advantage in CT Angiography by decreasing radiation dose and contrast material volume, which is particularly beneficial for renally impaired patients, minimizing the need for time-consuming and high-cost after-care procedures (e.g., monitoring and renal function tests) 100 kV Large Range CTA Stent surgery follow up exam, severe stenosis of celiac trunk. CTDIvol
Enquire about this product ↗At a glance
Clear specs.
Better decisions.
Use these core specifications as a guide. Contact our team for full technical sheets, options and regional availability.
Feature 1Lower kV presents a diagnostic advantage in CT Angiography by decreasing radiation dose and contrast
material volume, which is particularly beneficial for renally impaired patients, minimizing the need for time-consuming and high-cost after-care procedures (e.g., monitoring and renal function tests)
Feature 2Stent surgery follow up exam, severe stenosis of celiac trunk.
CTDIvol6.4 mGy, DLP: 241.1 mGy*cm, Effective dose: 0.75 mSv
Feature 4Reexamination after aortic dissection stenting.
Feature 6Right vertebral artery narrow.
Feature 8Market-leading high definition imaging solutions and innovations are brought together in NCT series, delivering clear visualization of subtle structures, early detection of micro-lesions and exceptional clinical outcomes.
Feature 9Narang Medical is continuously innovating state-of-the-art Reconstruction Algorithms for image clarity.
Feature 10For neuro imaging, NCT series delivers the speed and accuracy, enabling fast life-saving interveution decisions with detailed display of brain structures.
Feature 11For lung imaging, low-dose high definition acquisition enables CT lung cancer screening more accessible to high-risk, asymptomatic individuals.
Feature 12For abdomenal imaging, NCT series's balanced imaging chain offers defined edges and natural contouring for every clinical anatomy and lesions, essentially enhancing diagnostic confidence.
Feature 13For orthopedic imaging, fast scan time, long scanning range, consistent image quality with a significant dose reduction benefit are the keys to reliable diagnostic outcomes for trauma patients who are potentially in a lot of pain and require immediate care.
Feature 14With the assistance of Spectral Imaging, NCT series allows acquisition of both anatomical and functional information, providing better contrast images, metal artifact reduction, material separation and affirmation of eff-Z number, resulting in major gains in specificity and diagnostic accuracy.
Feature 15With an examination set up as simple as a regular spiral scan, Spectral Imaging adds valuable quantitative information to the morphology of conventional CT scans, providing material decomposition that can prove useful for gout visualization.
Feature 16Imaging patients with metal implants has long been a challenge for all modalities. NCT series powered by Spectral Imaging can significantly reduce beam hardening artifacts through monochromatic energy synthesis, resulting in outstanding image quality with valuable diagnostic information.
Feature 17NCT series utilizes intelligent power management design to optimize power consumption during scanning and reduces stand-by power consumption, in combination with effective electricity transmission system, resulting in 12% power usage reduction. Decreased energy requirements lowers operational costs while minimizing the environmental footprint contributing to a greener planet.
Feature 18Tube heat capacity…………………………3.5 MHU
Feature 19Generator power…………………….….....…32 kW
Feature 20kV steps………………………………………...……..60, 70, 80, 100, 120, 140 kV
Feature 21mA range………………………………………...……10-320 mA
Feature 22Slices………………………………………………………16 slices
Feature 23Rotation time…………………………………..…0.71 s/360°
Feature 24Spatial resolution………………………………15 lp/cm @ 0% MTF
Feature 25Low contrast resolution…………………2 mm @ 0.3%
Ready to specify NCT16?